Problem
Possible Causes
Remedy
no signal of servo board
no power supply
make sure the power supply are correctly connected
burnt servo board after setup
wrong polarity
check polarity of power supply
rhythmed oscilliation behavior of scnanner with normal red light on
over-position protect
check the input signal voltage range
wrong trace conture of image field
improper ratio of input signal or other related problem with input signal
check the ratio of input signal
interference in scan trace contour
1 wrong cable connection
check the cable connection
 
2 problem with grounding
make sure the grounding line is properly connected
 
3 strong ambient source of interference
make sure there is no strong ambient interference source
 
4 low anti-interference ability of D/A control card
check the anti-interference of D/A control card
low power or no beam out of lazer
deflecting mirror or its cover maybe damaged
check the mirrors
 
 

 

 

 

 